Model 10887A Isolated Repeater

Model 10887A Isolated Repeater

This model works with unmodulated IRIG-B and isolates the source from the end device.

 

Model 10887A Data Sheet
Download PDF(1 MB) »

Self-Monitor, IRIG-B Distribution System, and Second RS-232
Download PDF(19 kB) »

While not technically part of the Copper IRIG-B Distribution System, Model 10887A is derived from it. It works with unmodulated IRIG-B and isolates the source from the end device.

  • Limits the load current drain on the source.
  • Drives mulitple loads in parallel.
  • Has 75 mA of drive capability from each of the two outputs.
  • Output connectors can be either BNC or pluggable terminal strip, chosen at time of order.
  • Optional DIN rail mounting.

I/O Configuration

Output Connectors

Pluggable terminal strip or BNC

Output Signals

  • +5 Volt CMOS via two standard pluggable terminal block or BNC
  • 75 mA maximum per output
  • 10 ohm impedance

Input Connectors

Pluggable terminal strip or BNC

Input Signals

+5 Volt CMOS @ 5 mA via one standard pluggable terminal block or BNC connector.

Interface

Operator

Status LEDs
  • Data LED
  • Power LED

Power Requirements

Power Input

+9 to +13.5 Vdc, 70 mA; input power connector, tip positive

Power Supply

Choose one from the Accessories Tab

General

Physical

Size
  • Without DIN rail: 50 × 38 × 50 mm (2.0 × 1.5 × 2.0 in.), overall height including connectors.
  • With DIN rail & BNC: 51 × 43 × 72 mm (2 × 1.69 × 2.83 in.)
  • With DIN rail & Pluggable terminals: 51 × 43 × 63 mm (2 × 1.69 × 2.48 in.)
Weight

With BNC connectors and without DIN rail mounts: 94 g (3.30 oz.)

Environmental

Temperature

Operating: -10° C to +50° C
Nonoperating: -40° C to +75° C

I/O
10887Aopt01 Isolated Repeater (BNC Input and BNC Output)
10887Aopt02 Isolated Repeater (Pluggable Terminal Input and BNC Output)
10887Aopt03 Isolated Repeater (BNC Input and Pluggable Terminal Output)
10887Aopt04 Isolated Repeater (Pluggable Terminal Input and Pluggable Terminal Output)
General
10887AoptDIN DIN Rail Clips
Available
10886A IRIG-B Distribution Cable 300 m (1000 ft)
AP0004200 Wall-mount Power Supply: 110-120 Vac, 50-60 Hz; 9 Vdc, 0.66 A
AP0006200 1 Power Supply: 72-140 Vdc, IEC-320; 12 Vdc, 0.7 A
AP0009500 2 Power Supply: 100-240 Vac, 50-60 Hz, IEC-320; 9 Vdc, 1 A
AS0094400 Power Supply 18-72 Vdc; 12 Vdc, 0.833 A
CA0026000 3 Power Cord for AP0006200 DC Application
P01-P10 Country specific power cord with straight female end
WC0006600 IRIG-B Distribution Cable (custom length)

1 Used in conjunction with CA0026000
2 Used in conjunction with P01 - P10
3 For use with AP0006200

Distributing Timing Signals in a High-EMI Environment
Download application_note_101.pdf (68 kB) »

Quick Model Search
Search Arbiter.com
 advanced search help »


phone
(US, Canada, Mexico only) 800.321.3831 +1.805.237.3831

email
sales@arbiter.com

Find a Local Representative