Model 10887A Isolated Repeater
Model 10887A Isolated Repeater
This model works with unmodulated IRIG-B and isolates the source from the end device.
Model 10887A Data Sheet
Download PDF(1 MB) »
Self-Monitor, IRIG-B Distribution System, and Second RS-232
Download PDF(19 kB) »
While not technically part of the Copper IRIG-B Distribution System, Model 10887A is derived from it. It works with unmodulated IRIG-B and isolates the source from the end device.
- Limits the load current drain on the source.
- Drives mulitple loads in parallel.
- Has 75 mA of drive capability from each of the two outputs.
- Works with all Arbiter GPS satellite-controlled clock products.
- Output connectors can be either BNC or pluggable terminal strip.
- Optional DIN rail mounting.
Ordering checklist:
- Required:
- Input Connector: Choose BNC or Pluggable Terminal Strip.
- Output Connector: Choose BNC or Pluggable Terminal Strip.
- Power Supply: Choose from the many listed under the Accessories tab.
Note: Not all power supplies have DIN Rail mounting available.
- Optional (Must be chosen at time of order):
- DIN Rail Mounting for the 10887A module. Look on the Options tab for ordering information.
- DIN Rail Mounting for select power supplies. Look on the Accessories tab for power supply details.
I/O Configuration
Output Connectors
Pluggable terminal strip or BNC
Output Signals
- + 5 Volt CMOS via two standard pluggable terminal block or BNC
- 75 mA maximum per output
- 10 ohm impedance
Input Connectors
Pluggable terminal strip or BNC
Input Signals
+ 5 Volt CMOS @ 5 mA via one standard pluggable terminal block or BNC connector.
Interface
Operator
Status LEDs |
|
Power Requirements
Power Input
+ 9 Vdc to + 13.5 Vdc, 70 mA; input power connector: 3.5 mm male, tip positive
Power Supply
A power supply is required. Choose one from the Accessories tab.
General
Physical
Size | Without DIN Rail: BNC with DIN Rail: Pluggable Terminal Strip with DIN Rail: |
Weight | With BNC connectors and without DIN rail mounts: 76 g (3.2 oz) |
Environmental
Temperature | Operating: - 10 °C to + 50 °C |
I/O | |
---|---|
10887Aopt01 | Isolated Repeater (BNC Input and BNC Output) |
10887Aopt02 | Isolated Repeater (Pluggable Terminal Input and BNC Output) |
10887Aopt03 | Isolated Repeater (BNC Input and Pluggable Terminal Output) |
10887Aopt04 | Isolated Repeater (Pluggable Terminal Input and Pluggable Terminal Output) |
General | |
10887AoptDIN | DIN Rail Clips |
Available | |
---|---|
AP0003400 1 | BNC (Male) Breakout to 100 mm Wires |
AP0004200 2 | Wall-mount Power Supply: 110-130 Vac, 50-60 Hz; 9 Vdc, 0.66 A |
AP0008900 3 | BNC (Female) Breakout to 100 mm Wires |
AP0009500 4 | Power Supply: 100 Vac to 240 Vac, 50 Hz to 60 Hz, IEC-320; 9 Vdc, 1 A |
AP0014900 5 | BNC (Female) Breakout to Screw Terminal |
AP0015000 6 | BNC (Male) Breakout to Screw Terminal |
AS0094400 7 | Power Supply 18-72 Vdc; 12 Vdc, 0.833 A |
AS0094402 8 | Power Supply 18-72 Vdc; 12 Vdc, 0.833 A, with DIN Rail Mounting |
AS0096800 9 | Power Supply 85-264 Vac RMS or 110-370 Vdc; 12 Vdc, 0.9 A |
AS0106600 | DIN Rail Mounting Kit for AS0096800 |
CA0031900 | 2 m (6.5 ft) 2 Wire, 22 AWG Cable, Bare to Bare |
CA0031901 | 2 m (6.5 ft) 2 Wire, 22 AWG Cable, Bare to Spade |
CA0031902 | 2 m (6.5 ft) 2 Wire, 22 AWG Cable, Bare to 3.5 mm Male Plug |
CA0031903 | 2 m (6.5 ft) 2 Wire, 22 AWG Cable, Spade to 3.5 mm Male Plug |
CA0032000 | 2 m (6.5 ft) 3 Wire, 22 AWG Cable, Bare to Spade |
CA0032001 | 2 m (6.5 ft) 3 Wire, 22 AWG Cable, Spade to Spade |
P01 - P10 | Country specific power cord with straight female end |
1 Converts female BNC-terminated coaxial cable to pair of wires.
2 DIN Rail Mounting Kit Not Available
3 Converts male BNC-terminated coaxial cable to pair of wires.
4 DIN Rail Mounting Kit Not Available. Requires additional cabling for a complete solution. Recommendation: P01 - P10.
5 Converts pair of wires to female BNC.
6 Converts pair of wires to male BNC.
7 DIN Rail Mounting Kit Not Available. Requires additional cabling for a complete solution. Recommendation: CA0031901 and CA0031902.
8 DIN Rail Mounting Kit Available. Requires additional cabling for a complete solution. Recommendation: CA0031901 and CA0031902.
9 DIN Rail Mounting Kit Available. Requires additional cabling for a complete solution. Recommendation: CA0032001 and CA0031903.
Distributing Timing Signals in a High-EMI Environment
Download application_note_101.pdf (68 kB) »