The Arbiter Systems®, Inc. Model 1040C and 1040CU Panel Meter Calibrator (PMC) is discontinued. We will provide repair and calibration services through 2022 depending upon parts availability.
The accessories listed below are still available for purchase.
- Calibrates panel meters, transducers, circuit breakers and overcurrent relays
- Rugged, portable for field work
- 1040C includes hand-held controller for remote/distance operations
- Works with external standard Model 931A
- Self-test and diagnostics built-in
- Supports complex measurement sequences with included store-recall memory function
Output Signals
Voltage
Output Range | 10 mVdc to 1050 Vdc |
Accuracy | ± (0.2 % setting + 0.05 % FS) (dc) ≤ 150 Vrms ± (0.2 % setting + 0.05 % FS) Note: Internal voltage ranges have full-scale (FS) values of 105 mV, 1.05 V, 10.5 V, 105 V, and 1050 V (dc), and 15.75 Vrms, 157.5 Vrms, and 750 Vrms (ac). |
Burden | 15 mA; ≥ 25 mA overload (dc) ≤ 150 Vrms 300 mArms |
Noise (dc) | ≤ 0.25 % setting; 10 kHz BW |
Distortion | ≤ 0.45 % |
Auxiliary Voltage
Synchroscope Output is connected to the Voltage Output with a selectable 0 ° or 180 ° phase relationship. The total burden of both outputs must not exceed specification.
Current
Output Range | 0.1 mA to 10.5 Adc |
Accuracy | ± (0.2 % setting + 0.05 % FS) (dc) ≤ 1.05 Arms ± (0.2 % setting + 0.05 % FS) Note: Internal current ranges have full-scale (FS) values of 1.05 mA, 10.5 mA, 105 mA, 1.05 A, and 10.5 A (dc), and 1.05 Arms, and 7.5 Arms (ac). |
Compliance | Vrms; 6.5 V overload (ac) ≤ 50 mAdc 12 Vdc; 12.5 V overload |
Noise (dc) | ≤ 0.25 % setting; 10 kHz BW |
Distortion | ≤ 0.45 % |
Frequency - AC Operation
Ranges | 50 Hz to 75 Hz |
Accuracy | ≤ 0.01 % |
General
Stability | ≤ (0.03 % setting + 0.015 % FS) (see Notes under the Voltage and Current headings) averaged one minute or longer |
Resolution | ≤ 0.1 % setting |
Settling Time | 8 seconds maximum |
AC Power, VARs
Range | 1.5 VA to 5625 VA |
Current | 0.1 Arms to 7.5 Arms |
Voltage | 15 Vrms to 750 Vrms |
Phase Angle | + 180 ° to - 180 ° |
Phase Accuracy | ± 0.33 ° |
Stability | ≤ (0.06 % setting + 0.03 % FS) averaged one minute or longer. Note: Full-Scale (FS) value determined from full-scale values of voltage and current ranges being used. Other ac power specifications are derived from the individual specifications for current and voltage. |
Phase , Power Factor
Phase Angle | + 180 ° to - 180 ° |
Phase Accuracy | ± 0.33 ° |
Phase Stability | ≤ 0.2 ° rms, averaged one minute or longer |
Resolution | ≤ 0.1 ° |
Interface
Operator
Display | 20-character alphanumeric VFD |
Display Mode | Normal, deviation(%), reset |
Keypad | Front-panel numeric keyboard |
Instrument Mode | DC, 60 Hz, and 400 Hz |
Function | Voltage, current, synchroscope, power, reactive power, frequency, power factor, & phase |
Output | Standby (outputs disabled) |
Connectors | Detachable, 3 m cables (1040C) |
Synchroscope | 0 ° or 180 ° (selectable) |
Hand-Held Unit | (1040C only) Store, recall, up, down, operate, standby, normal and % deviation keys. |
System Interface
Computer | IEEE-488 |
Power Requirements
External
Range | 115 Vrms ± 10 %, 47 Hz to 500 Hz |
General
Physical
Instrument/Size | 38 cm x 38 cm x 28 cm (15 in x 15 in x 11 in) |
Weight | 17 kg (38 lbs), net |
Environmental
Temperature | Operating: 0 °C to 55 °C |
Available | |
---|---|
AS0000300 1 | Meter Adapter 1/4-20 (4 ea) |
AS0000400 1 | Meter Adapter 10/32 (4 ea) |
AS0011303 2 | 1040C Hand-held control unit with 3 m cable |
AS0012900 1 | Service Kit |
AS0020100 3 | 1040C/1040CU Maintenance Manual |
AS0020200 4 | 1040C/1040CU Operation Manual |
AS0058500 5 | Hand-Held Control Unit for 1040CU |
CA0005606 6 | 6 m 1040C Voltage Cable |
CA0005703 2 | 3 m 1040C Current Output Cable |
CA0005706 6 | 6 m 1040C Current Output Cable |
CA0011103 6 | 3 m 1040C Hand-Held Control Unit Extension Cable |
P09R 4 | Power Cord, North America, Right Angle |
1 Available for both Model 1040C and 1040CU
2 Included with Model 1040C
3 Included with Model 1040C, Available for Model 1040CU
4 Included with both Model 1040C and 1040CU
5 Available for Model 1040CU Only
6 Available for Model 1040C only
No additional software information is available for this product
No additional firmware information is available for this product
Training: Calibrating Meters and Transducers with Model 1040C/CU
Download 1040c_training2_calibrating_meters_transducers.pdf (270 kB) »
Training: Model 1040C Panel Meter Calibrator
Download 1040c_training1.pdf (344 kB) »