Options - Option 08 10 Vdc to 60 Vdc Terminal Power Strip and Surge Withstand

Summary Information


Replaces the standard power supply with one accepting 10 Vdc to 60 Vdc, 3 VA typical. Replaces standard IEC-320 inlet with a 3-pole terminal strip. Provides input surge protection (SWC) for compliance with ANSI C37.90-1 and IEC 801-4. Operates from common low-voltage battery systems, including 12 Vdc, 24 Vdc, and 48 Vdc. Available on the Models 1073A, 1084A/B/C, 1093B/C, and 1094B.

Full Description


10 Vdc to 60 Vdc Terminal Power Strip and Surge Withstand, as installed on rear of chassis.

Option 08 replaces the standard IEC-320 power inlet module with a three-position, screw-type terminal block, including Surge Withstand Capability (SWC). With DC ONLY inlet voltages from 10 Vdc to 60 Vdc, this feature is intended for use in installations where it is necessary or desirable to have the instrument power hard-wired.

Specifications

Input Power

  • DC Voltage: 10 Vdc to 60 Vdc.
  • Input Power: < 20 Watts, typical.

Terminal Strip

  • Terminal Assignment: Ground, (−), (+). Left to right, viewed from rear.
  • Block Size: 49 mm W x 15mm H x 16.5 mm D. (1.9 in x 0.6 in x 0.6 in)
  • Block Material: Glass-filled thermoplastic.
  • Screw Size: 6–32 x 0.25 in
  • Screw Material: Cadmium-plated steel.
  • Terminal Spacing: 9 mm (0.35 in).
  • Approvals: U.L. recognized; C.S.A. approved.

Fuse

  • Type: Bussman GDC-1A.
  • Current Rating: 1 Ampere, time lag.
  • Voltage Rating: 250 Volts.
  • Size: 5 mm x 20 mm.

Surge Withstand Protection (SWC)

Provides input Surge Withstand Capability (SWC) in compliance with both ANSI C37.90 and IEC 801-4.

BACK