Model 10881A Fiber-Optic to Logic Adapter

Model 10881A Fiber-Optic to Logic Adapter

Supports transmission of a digital signal over several kilometers and conversion to a + 5 V CMOS logic level output signal.

   

Model 10881A Data Sheet
Download PDF(1 MB) »

Self-Monitor, IRIG-B Distribution System, and Second RS-232
Download PDF(19 kB) »

The Model 10881A Fiber-Optic to Logic Adapter allows transmission of a digital signal over several kilometers and upon receiving, for the conversion to a + 5 V CMOS logic levl output signal. One optical signal is received and simultaneously sent as an electrical signal on two separate, individually-buffered BNC or Pluggable Terminal (shown above) output connectors.

The signal logic level is HI whenever the optical signal is ON. Whenever optical data is received the Data LED Iluminates (flashes).

  • Support for long distance transmission (several kilometers)
  • Can be used with any Arbiter GPS satellite controlled clock
  • Select BNC or Pluggable Terminal output connectors
  • Can be used with DIN Rail mounting brackets
  • Specified with 50/125 μm, 62.5/125 μm, 100/140 μm, and 200 μm PCS Fiber.

Ordering checklist:

  • Required:
    • Output Connector: Choose BNC or Pluggable Terminal Strip.
    • Power Supply: Choose from the many listed under the Accessories tab.
      Note: Not all power supplies have DIN Rail mounting available.
  • Optional (Must be chosen at time of order):
    • DIN Rail Mounting for the 10881A module. Look on the Options tab for ordering information.
    • DIN Rail Mounting for select power supplies. Look on the Accessories tab for power supply details.

I/O Configuration

Output Connectors

Two standard BNC connectors or two pluggable terminal strips

Output Signals

+ 5 V CMOS signal

Input Connectors

One type ST fiber optic connector

Input Signals

Fiber-optic signal via a 62.5/125 μm fiber, - 10 to - 24 dBm input level

Note: Also usable with 50/125 μm, 100/140 μm, and 200 μm PCS fiber

Connector Notes

Impedence: 10 ohms

Current: ± 75 mA maximum

Power Requirements

Power Input

+ 9 Vdc to + 13 Vdc

Power Supply

A power supply is required. Choose one from the Accessories tab.

General

Physical

Size

Without DIN Rail:
50 mm x 38 mm x 50 mm (2.0 in x 1.5 in x 2.0 in) overall dimensions, including connectors

With DIN Rail:
50 mm x 38 mm x 70 mm (2.0 in x 1.5 in x 2.8 in) overall dimensions, including connectors

Weight

Without DIN Rail:
76 g (2.7 oz)

With DIN Rail:
83 g (3.2 oz)

Environmental

Temperature

Operating: - 10 °C to + 50 °C

Nonoperating: - 40 °C to + 75 °C

I/O
10881Aopt01 Two BNC output connectors
10881Aopt02 Two pluggable terminal strip output connectors
General
10881AoptDIN DIN Rail Clips
Available
10886A IRIG-B Distribution Cable 300 m (1000 ft)
AP0003400 1 BNC (Male) Breakout to 100 mm Wires
AP0004200 2 Wall-mount Power Supply: 110-130 Vac, 50-60 Hz; 9 Vdc, 0.66 A
AP0008900 3 BNC (Female) Breakout to 100 mm Wires
AP0009500 4 Power Supply: 100 Vac to 240 Vac, 50 Hz to 60 Hz, IEC-320; 9 Vdc, 1 A
AP0014900 5 BNC (Female) Breakout to Screw Terminal
AP0015000 6 BNC (Male) Breakout to Screw Terminal
AS0094400 7 Power Supply 18-72 Vdc; 12 Vdc, 0.833 A
AS0094402 8 Power Supply 18-72 Vdc; 12 Vdc, 0.833 A, with DIN Rail Mounting
AS0096800 9 Power Supply 85-264 Vac RMS or 110-370 Vdc; 12 Vdc, 0.9 A
AS0106600 DIN Rail Mounting Kit for AS0096800
CA0031900 2 m (6.5 ft) 2 Wire, 22 AWG Cable, Bare to Bare
CA0031901 2 m (6.5 ft) 2 Wire, 22 AWG Cable, Bare to Spade
CA0031902 2 m (6.5 ft) 2 Wire, 22 AWG Cable, Bare to 3.5 mm Male Plug
CA0031903 2 m (6.5 ft) 2 Wire, 22 AWG Cable, Spade to 3.5 mm Male Plug
CA0032000 2 m (6.5 ft) 3 Wire, 22 AWG Cable, Bare to Spade
CA0032001 2 m (6.5 ft) 3 Wire, 22 AWG Cable, Spade to Spade
P01 - P10 Country specific power cord with straight female end
WC0006600 IRIG-B Distribution Cable (custom length)

1 Converts female BNC-terminated coaxial cable to pair of wires.
2 DIN Rail Mounting Kit Not Available
3 Converts male BNC-terminated coaxial cable to pair of wires.
4 DIN Rail Mounting Kit Not Available. Requires additional cabling for a complete solution. Recommendation: P01 - P10.
5 Converts pair of wires to female BNC.
6 Converts pair of wires to male BNC.
7 DIN Rail Mounting Kit Not Available. Requires additional cabling for a complete solution. Recommendation: CA0031901 and CA0031902.
8 DIN Rail Mounting Kit Available. Requires additional cabling for a complete solution. Recommendation: CA0031901 and CA0031902.
9 DIN Rail Mounting Kit Available. Requires additional cabling for a complete solution. Recommendation: CA0032001 and CA0031903.

Distributing Timing Signals in a High-EMI Environment
Download application_note_101.pdf (68 kB) »

Quick Model Search


phone
(US, Canada, Mexico only) 800.321.3831 +1.805.237.3831

email
sales@arbiter.com

Find a Local Representative