Clock Option Selection Guide - Matrix of clocks and associated options
Precision Clock Selection Guide - Matrix of technical specifications and clock models
The breadth of Arbiter Systems® products are designed to fill common needs across most applications and environments. When the need arises for solutions beyond the standard, look to Options and Accessories to economically customize your solution. Options include individual and dual NTP servers, COMTRADE Sample Rate Generator, Out-Of-Lock relay support, additional outputs, IRIG-B inputs, and more.
Special options or requirements can be accommodated; contact technical support for details and pricing. See the Option Selection Guide, product listings and individual data sheets for available options per product and ordering information.
The following Option descriptions are organized by Category and sub-category. Options are typically installed inside the unit by trained Arbiter technicians, and are commonly ordered at the time of purchase. Some field installations may be possible; contact Technical Support for assistance and more information.
Options for Timing and Frequency Products
I/O
Opt01 Fiber-Optic Input
Provides an 820 nm, Type ST optical fiber input for channel A. Available for Model 1073A
Details »Opt03 Four Additional Configurable Outputs
Adds four more individually-buffered BNC outputs, jumper-selectable to any signal available on the clock Main Board. Available on the Models 1084, 1088 and 1093.
Details »Opt04 Parallel BCD Output, 1 ms Resolution (1088B)
Provides a 50-pin ribbon connector with 42 data lines representing BCD time from day of year through milliseconds. Also provides 1 ms and 1 second output sync (strobe) pulses. Available on Model 1088B.
Details »Opt06 Parallel BCD Output, 1 ms Resolution
Provides a 50-pin ribbon connector with 42 data lines representing BCD time from day of year through milliseconds. Also provides 1 ms and 1 second output sync (strobe) pulses. Available on Models 1084A/B/C.
Details »Opt09 Frequency/Time Interval Measurement
Adds the capability to measure frequency and time intervals via one 50 ohm or hi-impedance input. Available on the Model 1083B.
Details »Opt17 Parallel BCD with Second RS-232 Port
Adds an RS-232 channel to the 'Parallel BCD Output'. Available on the Models 1084 and 1088.
Details »Opt17A Second RS-232 Port (1088B)
Adds a second RS-232 channel with a 9-pin male D-subminiature connector. Available on the Model 1088B.
Details »Opt18 Self-Monitor, IRIG-B Distribution System and Redundant Control with Second RS-232 Port
Provides a separate IRIG-B distribution bus with self-monitoring capabilities. Available on the Model 1088B.
Details »Opt19 Out-of-lock Relay 1 Form C SPDT [1088B]
Adds a relay (Form C) and 3-pole terminal strip on the rear panel. Available on the Model 1088B, Slot B.
Details »Opt19 Second RS-232 Port
Adds a second RS-232 channel with a 9-pin male D-subminiature connector. Available on the Models 1084, 1092 and 1093.
Details »Opt20 Fiber-Optic, Type ST 820 nm
Provides a selectable fiber-optic output with Type ST connector and 820 nm transmitter compatible with multimode fiber. Available on the Model 1084A/B/C.
Details »Opt20A Four Configurable Fiber-Optic Outputs
Provides four, individually-selectable fiber-optic outputs with Type ST connectors and 820 nm transmitters compatible with multimode fiber (typically 62.5/125 µm). Available on the Models 1084A/B/C, 1088B, and 1093A/B/C.
Details »Opt23 COMTRADE Sample Rate Generator
Provides a GPS-synchronized sampling signal at rates of 200 PPS to 192 kPPS, as defined in IEEE Standard C37.111-1991. Available on the Models 1084, 1088.
Details »Opt27 8-Channel High Drive IRIG-B Output
Adds eight independent, buffered outputs, each capable of driving multiple loads. Available on the Models 1084A/B/C, 1088B, and 1093A/B/C.
Details »Opt28 Power System Time, Frequency, and Phase Monitor
Accepts either a 60 Hz or 50 Hz, 30 to 300 Vrms signal, and measures the instantaneous phase and frequency of the fundamental component. Available on the Models 1084, 1088, and 1093.
Details »Opt29 Four Additional Outputs with Dry Contact and +25/50 Vdc
Adds four standard, 5 V CMOS outputs and two Aromat AQV210E solid-state relays. Available on the Models 1084, 1088, and 1093
Details »Opt32 Internal Network Time Protocol (NTP) Server -DISCONTINUED-
Provides a GPS-synchronized, stratum level 1, network time protocol (NTP) server with one (Option 32) or two (Option 33) 10/100Base-T Ethernet connector(s). Available on Models 1084, 1088 and 1093.
Details »Opt33 Dual Internal Network Time Protocol (NTP) Server -DISCONTINUED-
Similar to Opt32, Opt33 has two identical and independent NTP servers. Available on Models 1088B, 1084 and 1093
Details »Opt34 Network Time Protocol (NTP) / Precision Time Protocol (PTP) Server
Provides GPS-synchronized, stratum level 1 Network Time Protocol or Precision Time Protocol - PTP (IEEE 1588) on two 10/100BT or SSF Fiber Ethernet connectors. Available on Models 1084, 1088 and 1093.
Details »Opt92 IRIG-B Modulated Output
Adds a Modulated Inter-Range Instrumentation Group Format B (IRIG-B) distribution bus. Available on the Models 1092A/B/C and 1093A/B/C.
Details »Opt93 Out-of-lock Relay 1 Form C SPDT
Adds a relay (Form C) and 3-pole terminal strip on the rear panel. Available on the Models 1092 and 1093.
Details »Opt94 RS-422/485 Driver
Provides RS-422/485 line driver output at the standard serial port with the standard RS-232 output. Available on Models 1093A/B/C and 1092A/B/C.
Details »Opt95 Four BNC Connectors, (Parallel to Pluggable Terminal Strip)
Provides three BNC output connectors and one BNC input connector. Available on Model 1093A/B/C
Details »Opt96 1 PPS Output Reconfigured to Programmable Pulse
Converts the 1-PPS output to programmable pulse. Available on Models 1093A/B/C and 1092A/B/C
Details »Opt97 IRIG-B Output Reconfigured to Programmable Pulse
Reconfigures the IRIG-B unmodulated output to programmable pulse. Available on Models 1093A/B/C and 1092A/B/C
Details »Opt98 1 PPS Output Reconfigured to Event Input
Converts Event Input from IRIG-B modulated output. Available on Models 1093 and 1092
Details »Optxy 1 MHz Sine Wave, BNC
Available on Model 1083B.
Details »Optxy 5 MHz Sine Wave, BNC
Available on Model 1083B.
Details »Optxy 10 MHz Sine Wave, BNC
Available on Model 1083B.
Details »General
Opt01 LCD Backlight
Operation is controlled from the keyboard, and may be continuous ON, OFF, or automatic: on for 30 seconds after any key is pressed. Backlight life - 2000 hours, continuous operation. Available on the Models 1084B/C, 1088B, 1092B and 1093B/C. This is standard on Model 1094B
Details »Opt01 LCD Backlight (1092B)
For use with 1092 version B only
Details »Opt02 Smoked Enclosure Cover (1095A)
For Model 1095A
Details »Opt02 Opaque Enclosure Cover (1095C)
For Model 1095C
Details »Opt04 On/Off Switch (1084A/B/1093A/B)
Provides for a front panel On/Off Line switch. Available on the Models 1084A/B, and 1093A/B ONLY. (On/Off front panel swith is not available on the C version of the two models)
Details »Power
Opt07 IEC-320 Power Inlet 85 to 264 Vac RMS, 110 to 370 Vdc
Provides an ac/dc power module which includes an IEC-320 type inlet and mating cordset. Input voltages are: 85 to 264 Vac RMS, 47 to 440 Hz or 110 to 370 Vdc, 3 VA typical. Various plug styles are available as Options P01 through P10, see below. Available on the Models 1073A, 1084A/B/C, and 1093A/B/C.
Details »Opt07 85 to 264 Vac RMS, 110 to 370 Vdc Terminal Power Strip (1088B)
Includes a terminal strip, without surge withstand. For Model 1088B
Details »Opt08 10 to 60 Vdc Terminal Power Strip and Surge Withstand (1088B)
Replaces the standard power supply with one accepting 10 to 60 Vdc power. Replaces standard IEC-320 inlet with a dc terminal barrier strip. Operates from common low-voltage battery systems, including 12, 24, and 48 Vdc. Available on the Model 1088B.
Details »Opt08 10 to 60 Vdc Terminal Power Strip and Surge Withstand
Replaces the standard power supply with one accepting 10 to 60 Vdc, 3 VA typical. Replaces standard IEC-320 inlet with a 3-pole terminal strip. Provides input surge protection (SWC) for compliance with ANSI C37.90-1 and IEC 801-4. Operates from common low-voltage battery systems, including 12, 24, and 48 Vdc. Available on the Models 1073A, 1084A/B/C, and 1093A/B/C.
Details »Opt10 85 to 250 Vac RMS, 110 to 350 Vdc Terminal Power Strip and Surge Withstand
Replaces the standard IEC-320 inlet with a 3-pole terminal strip and provides input surge protection for compliance with ANSI C37.90-1 and IEC 801-4. Input voltages are: 85 to 264 Vac, 47 to 440 Hz, or 110 to 350 Vdc, 3 VA typical. Available on the Models 1083, 1084, and 1093.
Details »Opt15A 110 to 170 Vdc Terminal Power Strip and Surge Withstand (1088B)
Option 15A and 15B each replace the standard IEC-320 power input module with a three-position, screw-type terminal block, including Surge Withstand Capability (SWC). For use with Model 1088B.
Details »Opt15B 110 to 300 Vdc Terminal Power Strip and Surge Withstand (1088B)
Option 15A and 15B each replace the standard IEC-320 power input module with a three-position, screw-type terminal block, including Surge Withstand Capability (SWC). For use with Model 1088B.
Details »OptPSR Power/Receiver Module
The Power/Receiver module comes standard with an universal power supply that accepts inlet power from 85 to 264 Vac (47 - 440 Hz) or from 110 to 350 Vdc at less than 30 Watts. In addition to providing power, this module is equipped with a receiver for synchronizing time, by default GPS but optionally can be Galileo or GLONASS satellite systems. Optional high performance oscillators are also available on this module.
Details »Antenna
Opt01 External Antenna (1095A)
Removes internal antenna and provides AS0087800, CA0021306 and AS0048900
Details »Opt01 External Antenna (1095C)
Removes internal antenna and provides AS0087800, CA0021306 and AS0048900
Details »Oscillator
Opt12 Oven-Controlled Crystal Oscillator and Four Additional Outputs
Adds a medium-performance ovenized backup oscillator (OCXO) and four additional jumper-configurable outputs. Available on the Model 1088.
Details »
Options for Synchronized Power Measurement Products
I/O
Opt01 Input Module - CT input current module, 20 A direct with 5-way connectors
CT Input module for use with Model 933A
Details »Opt02 Input Module - CT Input current module with banana connectors
CT Input module for use with Model 933A
Details »Opt03 Input Module - CT Input current module with audio connectors
CT Input module for use with Model 933A
Details »Opt07 IRIG-B input: Replaces GPS receiver (1133A)
Available with Model 1133A
Details »Opt10 RS-232 (Port 1 - 1133A)
Available with Model 1133A, (Port 1)
Details »Opt11 RS-422/485 half-duplex (Port 1 - 1133A)
Available with Model 1133A
Details »Opt12 Modem (V.34bis, 33.6k) (Port 1 - 1133A)
Available with Model 1133A, (Port 1)
Details »Opt20 RS-232 (Port 2 - 1133A)
Available with Model 1133A, (Port 2)
Details »Opt21 RS-422/485 half-duplex (Port 2 - 1133A)
Available with Model 1133A, (Port 2)
Details »Opt22 Modem (V.34bis, 33.6k) (Port 2 - 1133A)
Available with Model 1133A, (Port 2)
Details »General
Opt01 16MB Internal Data Memory
Details »Opt02 32 MB memory
Details »Opt05 Mechanical output relays
Details »Opt06 Solid-State output relays (KYZ)
Details »Power
Opt03 85 to 250 Vac RMS, 110 to 350 Vdc Terminal Power Strip and Surge Withstand
For Model 1133A
Details »Opt04 10 to 60 Vdc Terminal Power Strip and Surge Withstand
For Model 1133A
Details »
Options for Power Measurement and Calibration Products
General
Opt01 16 MB memory
Additional memory for Models 931A and 930a allows units to become stand alone Trend Monitors. Required for use with PowerCSV Application Software option (opt01)
Details »OptCTCHAR CT Characterization
Characterizes the CT and provides a file to load into the Model 928A.
Details »
Options for Assembled Test Lead Products
General
OptC-Hook C-Hook Lugs, One End
Safety C-Hook Current Lead Sets answers customer requests for current leads that cannot be yanked loose from their connection to a terminal block.
Details »
Options for Fiber-Optic/Copper Signal Adapter Products
I/O
Opt01 Two BNC output connectors
Details »Opt02 Two pluggable terminal strip output connectors
Details »Opt01 Isolated Repeater (BNC Input and BNC Output)
Isolated Repeater (BNC Input and BNC Output)
Details »Opt02 Isolated Repeater (Pluggable Terminal Input and BNC Output)
Isolated Repeater (Pluggable Terminal Input and BNC Output)
Details »Opt03 Isolated Repeater (BNC Input and Pluggable Terminal Output)
Isolated Repeater (BNC Input and Pluggable Terminal Output)
Details »Opt04 Isolated Repeater (Pluggable Terminal Input and Pluggable Terminal Output)
Isolated Repeater (Pluggable Terminal Input and Pluggable Terminal Output)
Details »General
OptDIN DIN Rail Clips
DIN Rail Mounting Brackets. Must be ordered at time of purchase.
Details »